Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add filters








Year range
1.
Journal of Forensic Medicine ; (6): 584-588, 2022.
Article in English | WPRIM | ID: wpr-984150

ABSTRACT

OBJECTIVES@#To explore the development process of the postmortem interval (PMI) research in China from January 1990 to August 2020, research hotspots in different periods, authors and cooperation between institutions, and to provide a reference for the better development of PMI inference research through the visualization of the literature information of the PMI estimation research indexed in China National Knowledge Infrastructure (CNKI).@*METHODS@#The information visualization analysis software CiteSpace 5.7.R1 was used to carry out big data analysis on hotspots, high-frequency keywords, authors, institutions and other information in the research literature on PMI inference from January 1990 to August 2020 indexed in CNKI.@*RESULTS@#The peak time of publication of PMI was from 2006 to 2010 with 114 articles. In keyword co-occurrence network, the effective hot words were forensic entomology, DNA content analysis and some emerging words such as artificial intelligence and big data. In the cooperation network of institutions, the high-frequency institutions were mainly the scientific research institutions. The author cooperation network showed a trend of co-aggregation and multi-cooperation.@*CONCLUSIONS@#With the development of science and technology, the research on PMI estimation based on traditional methods is mature and novel strategies are emerging. Big data and artificial intelligence combined with forensic science provide new research directions on PMI estimation.


Subject(s)
Artificial Intelligence , Autopsy , China , Forensic Sciences , Software
2.
Journal of Forensic Medicine ; (6): 516-523, 2021.
Article in Chinese | WPRIM | ID: wpr-985242

ABSTRACT

Objective To establish a method combining QuEChERS and ultra-high liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) for rapid screening and testing of three types of new psychoactive tryptamines in human blood: 5-MeO-DALT, 5-MeO-MiPT and 5-MeO-DiPT. Methods The effects of the type of extractant, the type and dosage of salting-out agent, and the dosage of adsorbent on the test results of the three tryptamines were investigated. Blood samples were processed by QuEChERS method and then determined by UPLC-MS/MS. Results The linear relationships of 5-MeO-DALT, 5-MeO-MiPT and 5-MeO-DiPT in human blood were good in the range of 0.5-100, 0.5-100 and 0.2-100 ng/mL, respectively, with their coefficients higher than 0.99. The limits of detection (LODs) were 0.1-0.2 ng/mg. The recoveries ranged from 84.86% to 94.57%. Intra-day and inter-day precisions were good. Conclusion The method is simple, rapid, easy to operate and has a high recovery. It is suitable for the qualitative and quantitative study of tryptamines in blood and can provide the reference for public security organs to deal with related cases.


Subject(s)
Humans , Chromatography, High Pressure Liquid , Chromatography, Liquid , Limit of Detection , Tandem Mass Spectrometry , Tryptamines
3.
Journal of Forensic Medicine ; (6): 216-222, 2020.
Article in Chinese | WPRIM | ID: wpr-823438

ABSTRACT

Objective To investigate the maximum allowable deviations of retention time and ion abundance ratio of the 8 common drugs (poisons) from 3 categories, poisons (methamphetamine, morphine, ketamine), benzodiazepines (estazolam, midazolam, diazepam, clonazepam) and barbiturates (phenobar-bital) in blood, by liquid chromatograpy-tandem mass spectrometry (LC-MS/MS) in forensic toxicology analysis. Methods The deviations of retention time and ion abundance ratio at 7 low mass concentrations, limit of detection (LOD), 2LOD, limit of quantitation (LOQ), 1.5LOQ, 2LOQ, 4LOQ and 6LOQ, were tested by LC-MS/MS after liquid-liquid extraction under the conditions of two chromatographic columns and three chromatographs. Results The deviation of absolute retention time of 98.11% of 8 drugs (poisons) in the blood samples was within the range of ± 0.05 min, and that of the relative retention time of 96.21% was within the range of±0.4%. The maximum deviation of the ion abundance ratio was highly correlated with the mass concentration. When the mass concentration of drugs (poisons) was LOQ or above, more than 95% of the absolute deviation and relative deviation of the ion abundance ratio were in the range of±25% and±40%, respectively; when the mass concentration was below LOQ, the range could be expanded to±35% and±50%, respectively. Conclusion It is recommended for the determination range of the absolute retention time deviation of 8 common drugs (poisons) to be±0.1 min and that of the relative retention time deviation to be±1.0%. The determination range of absolute deviation of the ion abundance ratio should be±25% when the mass concentration is LOQ or above, and the relative deviation should be±40%. When the mass concentration is below LOQ, the deviation determination range can be expanded to±35% and±50%, respectively.

4.
Journal of Forensic Medicine ; (6): 687-694, 2019.
Article in English | WPRIM | ID: wpr-985064

ABSTRACT

Objective To investigate the maximum allowable deviation of ion abundance ratios of characteristic fragment ions in common drugs (poisons) in blood by gas chromatography-mass spectrometry (GC-MS) method. Methods Four common drugs (poisons) (dichlorvos, phorate, diazepam and estazolam) were detected by GC-MS full scan mode after liquid-liquid extraction in two laboratories and under three chromatographic conditions. The deviations of ion abundance ratios of the four common drugs (poisons) in marked blood samples with concentrations of 0.5, 1.0, 2.0, 5.0 and 10.0 μg/mL were analyzed. At the same time, the false negative rates of ion abundance ratios were analyzed when the mass concentration was limit of detection (LOD), 2LOD, limit of quantitation (LOQ) and 2LOQ, and the false positive rates of ion abundance ratios were analyzed with blank blood samples. Results Under the two laboratories, four common drugs (poisons) and three kinds of chromatography conditions, the differences in deviations of the ion abundance ratios of marked blood samples were not statistically significant (P>0.05). More than 95% of the absolute deviations of the ion abundance ratios of the marked blood samples were within the range of ±10%, and more than 95% of the relative deviations were within the range of ±25%. In cases of low concentration (concentration less than 2LOQ) or low signal to noise ratio (3-15), the false negative rate was less than 5% and the false positive rate was 0% when the relative deviation was greater than 50%. Conclusion The absolute deviations of ion abundance ratios of four common drugs (poisons) in marked blood samples are advised to have a determination range within ±10%, and the determination range of relative deviations within ±25%.


Subject(s)
Humans , Gas Chromatography-Mass Spectrometry , Ions/chemistry , Limit of Detection , Liquid-Liquid Extraction , Poisons/blood
5.
Chinese Journal of Hospital Administration ; (12): 257-262, 2010.
Article in Chinese | WPRIM | ID: wpr-379717

ABSTRACT

Objective To explore the status, characteristics and factors in relation to occupational stress for medical staffs in tertiary general hospitals. Methods A total of 2460 medical staff were sampled in five tertiary general hospitals in Beijing, with their occupational stress levels evaluated with the Occupational Stress Inventory. Results The top ten stressors as found ranked as heavy duty, high risk exposure, high workload, low wages, setbacks in the health care management system, insufficient staffing, excessively frequent inspections and examinations, strained doctor-patient relationship, price inflation, frequent overtime, and pressure from continuous learning. Occupational stress is seen as moderate and above by 95.2% of the surveyed. Differences in age, gender, marital status, professional title, education, work experience, as well as those of different organizations, departments, professions, and duty were found to be statistically significant in regard of professional stress. Conclusions Stress management should be in place targeting demographic and stress characteristics. Effective measures are recommended to alleviate the pressure on medical staff, in order to maintain their physical and mental health, hence improving their work efficiency and organizational cohesion.

6.
Chinese Journal of Hospital Administration ; (12): 425-427, 2009.
Article in Chinese | WPRIM | ID: wpr-380698

ABSTRACT

A satisfaction survey carried out by Beijing Chao-Yang Hospital during the Beijing 2008 Olympic Games, found differences of patient satisfaction between locals and overseas patients in consulting environment, outpatient procedure, quality of service, quality of diagnosis and treatment. The patient satisfaction of overseas patients was lower than locals. Especially noteworthy is the low satisfaction of the former for the hospital coloring, privacy in the sector, registration, vocal communication, patient condition statement, nurse attitude and service quality. Real-time improvement in these aspects of medical services has harvested obvious progress. Results of the satisfaction survey provided valuable reference materials for large-scale activities, and ongoing improvement of medical services in the long run.

SELECTION OF CITATIONS
SEARCH DETAIL